U/UTP Cat.6A 4Pr Outdoor
APPLICATION
PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Gigabit Ethernet (1000BASE-T, 1000BASE-TX), Firewire 100 Mbit/s, 2,5/5/10 Gigabit Ethernet (2.5/5/10GBASE-T), ATM LAN 1.2 Gbit/s
DESIGN
1) Conductor: solid bare copper, nominal diameter 0.565 mm
2) Insulation: HDPE, nominal diameter 1.01 mm
3) Pair: two conductors twisted together
4) Separator: HDPE cross-web, dimensions 4x4х0.34 mm
5) Jacket: flame retardant LSZH thermoplastic compound or flame retardant low smoke PVC, thickness 1.0 mm, nominal cable diameter 7.4 mm
СOMPLIANCE WITH THE REQUIREMENTS
System: ISO/IEC 11801, EN 50173-1, ANSI/TIA 568.2-D
Cable: IEC 61156-5, EN 50288-11-1, ANSI/TIA 568.2-D
MECHANICAL CHARACTERISTICS
Temperature range:
- During installation -10 °C ... +60 °C
- After installation -20 °C ... +60 °C
Bending radius:
- During installation ≥ 8 cable diameters
- After installation ≥ 4 cable diameters
Tensile stress ≤ 85 N
ELECTRICAL CHARACTERISTICS AT 20 °C
Parameter | Unit | Value |
Capacitance | pF/m | ≤ 56 |
Direct current resistance | Оhm/km | ≤ 83 |
Resistance unbalance | % | 2 |
Insulation resistance | GOhm/km | ≥ 5 |
Signal propagation velocity | % | 68 |
Characteristic impedance in the frequency range of: |
Ohm | 83 |
1-100 MHz | 100 +/-15 | |
100-250 MHz | 100 +/-22 | |
250-500 MHz | 100 +/-25 | |
Test voltage between cores, (DC, 2 s) | kV | 2,5 |
Frequency, MHz | 1 | 4 | 10 | 16 | 20 | 31,25 | 62,5 | 100 | 250 | 500 |
Attenuation, dB, max | 2,1 | 3,8 | 5,9 | 7,5 | 8,4 | 10,5 | 15 | 19,1 | 31,1 | 45,3 |
NEXT, dB, min | 75,3 | 66,3 | 60,3 | 57,2 | 55,8 | 52,9 | 48,4 | 45,3 | 39,3 | 34,8 |
PS NEXT, dB, min | 72,3 | 63,3 | 57,3 | 54,2 | 52,8 | 49,9 | 45,4 | 42,3 | 36,3 | 31,8 |
ELFEXT, dB, min | 68 | 56 | 48 | 43,9 | 42 | 38,1 | 32,1 | 28 | 20 | 14 |
PS ELFEXT, dB, min | 65 | 53 | 45 | 40,9 | 39 | 35,1 | 29,1 | 25 | 17 | 11 |
ORDER INFORMATION
P/N | Cable name | Jacket | Diameter of TPG, mm | Conductor diameter mm | Diameter / cable size, mm | Standard packing | Weight, kg/km |
7933095 | KPV-VP (500) 4*2*0,57 (U/UTP-cat.6А) | PE | 0,57 | 1,08 | 7,6 | Plywood reel 305/500/1000 m | 44,3 |